GuiSession


stationCode
uXiterFT_01
scandData
000005098,AS000018REVC023324
ATPName
uXIter_FT_ATP_Full_20241112_093412
startTime
11/14/2024 12:49:44
endTime
11/14/2024 12:49:54
Duration
00:10.557
Status
Fail

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.901
2 OC :: 12V to 4V DCDC Pass 00:00.000
3 Turn ON 12V source Pass Pass 00:00.032
4 Enable 4V DCDC Pass Pass 00:00.030
5 Delay 1000 Pass Pass 00:01.000
6 Read DUT 4V voltage rail -uX1 3800 3932 4100 Pass 00:00.465
7 Measure the current over 12v current rail 61 Pass 00:00.462
8 CC :: 12V to 4V DCDC Pass 00:00.000
9 Load 4V rail with external resistor Pass Pass 00:00.028
10 Delay 1000 Pass Pass 00:01.000
11 Read DUT 4V voltage rail -uX1 3064 Pass 00:00.454
12 Measure the current over 4v current rail 755 Pass 00:00.456
13 Turn off the external load Pass Pass 00:00.032
14 OC :: 4V to 3.3V LDO Pass 00:00.000
15 Enable 3.3V LDO Pass Pass 00:00.034
16 Delay 1000 Pass Pass 00:01.000
17 Read DUT 3.3V voltage rail 3100 3191 3360 Pass 00:00.457
18 Measure the current over 4v current rail 10 96 70 Fail 00:00.457
Back to List