GuiSession


stationCode
ReaderFT_01
scandData
000006308,AS000016REVC054424
ATPName
Reader2.0_FullATP_20241112_113709
startTime
11/13/2024 15:23:36
endTime
11/13/2024 15:23:43
Duration
00:06.916
Status
Fail

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.826
2 PoE : OC Pass 00:00.000
3 PoE : OC : Open circuit test :Turn on the 54V Pass Pass 00:00.196
4 PoE : OC : Set NXP RST Pass Pass 00:00.036
5 Delay 1000ms Pass Pass 00:01.000
6 PoE : OC : Read PoE+ voltage rail (PoE_P_ADC) (mv) 0 Pass 00:00.165
7 PoE : OC : PoE VDD voltage rail (PoE_VDD_ADC) (mv) 1 Pass 00:00.152
8 PoE : OC : PoE VDD voltage rail (PoE_VT15_ADC) (mv) 0 Pass 00:00.158
9 PoE : OC : Measure the current over 54V rail (Vbus54V) (mA) 32 Pass 00:00.027
10 PoE : OC : Read 4.6V rail voltage (ADC_4V6_Load) (mv) 4450 4549 4650 Pass 00:00.032
11 PoE : CC Pass 00:00.000
12 PoE : CC : turn on Load 4.6V rail with external resistor (Load4V6) Pass Pass 00:00.035
13 Delay 100ms Pass Pass 00:00.100
14 PoE : CC : Read PoE+ voltage rail (PoE_P_ADC) (mv) Skip Pass 00:00.000
15 PoE : CC : PoE VDD voltage rail (PoE_VDD_ADC) (mv) Skip Pass 00:00.000
16 PoE : CC : PoE VDD voltage rail (PoE_VT15_ADC) (mv) Skip Pass 00:00.000
17 PoE : CC : Measure the current over 54V rail (Vbus54V) (mA) 232 Pass 00:00.028
18 PoE : CC : Read 4.6V rail voltage (ADC_4V6_Load) (mv) 4287 Pass 00:00.041
19 PoE : CC : turn off Load 4.6V rail with external resistor (Load4V6) Pass Pass 00:00.024
20 PoE : CC : Open circuit test :Turn Off the 54V Pass Pass 00:00.022
21 PA 4.6V : OC Pass 00:00.000
22 PA 4.6V : OC : Turn on the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.022
23 Delay 500ms Pass Pass 00:00.500
24 PA 4.6V : OC : Read 4.6V PA voltage rail 4100 86 4600 Fail 00:00.039
Back to List