GuiSession


stationCode
uXiterFT_01
scandData
000006142,AS000018REVC023324
ATPName
uXIter_FT_ATP_Full_20241112_093412
startTime
11/13/2024 11:04:41
endTime
11/13/2024 11:04:52
Duration
00:10.846
Status
Fail

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.889
2 OC :: 12V to 4V DCDC Pass 00:00.000
3 Turn ON 12V source Pass Pass 00:00.029
4 Enable 4V DCDC Pass Pass 00:00.031
5 Delay 1000 Pass Pass 00:01.000
6 Read DUT 4V voltage rail -uX1 3800 4053 4100 Pass 00:00.456
7 Measure the current over 12v current rail 70 Pass 00:00.451
8 CC :: 12V to 4V DCDC Pass 00:00.000
9 Load 4V rail with external resistor Pass Pass 00:00.038
10 Delay 1000 Pass Pass 00:01.000
11 Read DUT 4V voltage rail -uX1 3190 Pass 00:00.463
12 Measure the current over 4v current rail 827 Pass 00:00.446
13 Turn off the external load Pass Pass 00:00.030
14 OC :: 4V to 3.3V LDO Pass 00:00.000
15 Enable 3.3V LDO Pass Pass 00:00.032
16 Delay 1000 Pass Pass 00:01.000
17 Read DUT 3.3V voltage rail 3100 3210 3360 Pass 00:00.455
18 Measure the current over 4v current rail 10 73 70 Fail 00:00.457
Back to List