GuiSession


stationCode
ReaderEOL_03
scandData
000006263,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 15:42:33
endTime
11/12/2024 15:47:02
Duration
04:29.018
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.257
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.324
5 ReaderReset Pass Pass 00:00.116
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.306
8 Reader Get Serial Number 000006263 Pass 00:00.108
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39001E4 Pass 00:00.217
11 SendReaderConfigFile Pass Pass 00:09.173
12 Get Main CPU version 2.1.1+1029 Pass 00:00.103
13 Get TX CPU version 0.15 Pass 00:00.108
14 Get BLE0 CPU version 0.10 Pass 00:00.105
15 Get BLE1 CPU version 0.10 Pass 00:00.101
16 Get BLE2 CPU version 0.10 Pass 00:00.128
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.812
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.108
21 ReaderTxGetTemp 32.25 Pass 00:00.100
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.413
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.317
26 Reader SyncTime Pass Pass 00:00.614
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.418
29 Get Last Spectrum Mesurment Amp 25 29.16 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.305
32 Reader SyncTime Pass Pass 00:00.615
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000910.14 928004000 Pass 00:00.383
35 Get Last Spectrum Mesurment Amp 25 29.89 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.417
38 Reader SyncTime Pass Pass 00:00.630
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.403
41 Get Last Spectrum Mesurment Amp 20 26.53 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.317
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.424
46 ReaderBLEtest ch 37 ant 1 -55 -41.45 -25 Pass 00:05.970
47 ReaderBLEtest ch 37 ant 2 -55 -39.45 -25 Pass 00:05.935
48 ReaderBLEtest ch 37 ant 3 -55 -41.45 -25 Pass 00:05.942
49 ReaderBLEtest ch 37 ant 4 -55 -34.02 -25 Pass 00:05.924
50 ReaderBLEtest ch 37 ant 5 -55 -39.45 -25 Pass 00:05.940
51 ReaderBLEtest ch 37 ant 6 -55 -33.47 -25 Pass 00:05.982
52 ReaderBLEtest ch 37 ant 7 -55 -41.89 -25 Pass 00:05.928
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.361
55 ReaderBLEtest ch 38 ant 1 -55 -39.42 -25 Pass 00:05.940
56 ReaderBLEtest ch 38 ant 2 -55 -31.45 -25 Pass 00:05.972
57 ReaderBLEtest ch 38 ant 3 -55 -41.45 -25 Pass 00:06.054
58 ReaderBLEtest ch 38 ant 4 -55 -31.45 -25 Pass 00:05.963
59 ReaderBLEtest ch 38 ant 5 -55 -38.45 -25 Pass 00:06.004
60 ReaderBLEtest ch 38 ant 6 -55 -35.45 -25 Pass 00:05.966
61 ReaderBLEtest ch 38 ant 7 -55 -37.45 -25 Pass 00:05.940
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.352
64 ReaderBLEtest ch 39 ant 1 -55 -38.43 -25 Pass 00:05.902
65 ReaderBLEtest ch 39 ant 2 -55 -36.45 -25 Pass 00:05.918
66 ReaderBLEtest ch 39 ant 3 -55 -41.49 -25 Pass 00:05.942
67 ReaderBLEtest ch 39 ant 4 -55 -37.49 -25 Pass 00:05.947
68 ReaderBLEtest ch 39 ant 5 -55 -35.45 -25 Pass 00:05.920
69 ReaderBLEtest ch 39 ant 6 -55 -32.12 -25 Pass 00:05.931
70 ReaderBLEtest ch 39 ant 7 -55 -33.45 -25 Pass 00:05.913
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.464
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.000
Back to List