GuiSession


stationCode
ReaderEOL_03
scandData
000005859,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 15:34:53
endTime
11/12/2024 15:35:23
Duration
00:29.968
Status
Error

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.236
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.318
5 ReaderReset Pass Pass 00:00.108
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.306
8 Reader Get Serial Number 000005859 Pass 00:00.101
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39002B7 Pass 00:00.220
11 SendReaderConfigFile Pass Pass 00:07.322
12 Get Main CPU version 2.1.1+1029 Pass 00:00.100
13 Get TX CPU version 0.15 Pass 00:00.101
14 Get BLE0 CPU version 0.10 Pass 00:00.102
15 Get BLE1 CPU version 0.10 Pass 00:00.107
16 Get BLE2 CPU version 0.10 Pass 00:00.105
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Unable to read data from the transport connection: A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond.. Error 00:07.682
Back to List