GuiSession


stationCode
ReaderEOL_03
scandData
000005850,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 15:12:34
endTime
11/12/2024 15:17:00
Duration
04:26.017
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.271
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.104 Pass 00:00.323
5 ReaderReset Pass Pass 00:00.100
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.104 Pass 00:00.321
8 Reader Get Serial Number 000005850 Pass 00:00.101
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39002C0 Pass 00:00.212
11 SendReaderConfigFile Pass Pass 00:07.093
12 Get Main CPU version 2.1.1+1029 Pass 00:00.100
13 Get TX CPU version 0.15 Pass 00:00.103
14 Get BLE0 CPU version 0.10 Pass 00:00.100
15 Get BLE1 CPU version 0.10 Pass 00:00.101
16 Get BLE2 CPU version 0.10 Pass 00:00.107
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.802
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.103
21 ReaderTxGetTemp 32 Pass 00:00.107
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.419
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.318
26 Reader SyncTime Pass Pass 00:00.638
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700122.20 865704000 Pass 00:00.423
29 Get Last Spectrum Mesurment Amp 25 29.25 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.325
32 Reader SyncTime Pass Pass 00:00.621
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000198.40 928004000 Pass 00:00.368
35 Get Last Spectrum Mesurment Amp 25 29.38 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.414
38 Reader SyncTime Pass Pass 00:00.603
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700122.20 865704000 Pass 00:00.389
41 Get Last Spectrum Mesurment Amp 20 26.56 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.304
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.366
46 ReaderBLEtest ch 37 ant 1 -55 -42.47 -25 Pass 00:05.952
47 ReaderBLEtest ch 37 ant 2 -55 -41.08 -25 Pass 00:05.909
48 ReaderBLEtest ch 37 ant 3 -55 -44.43 -25 Pass 00:05.960
49 ReaderBLEtest ch 37 ant 4 -55 -34.45 -25 Pass 00:05.919
50 ReaderBLEtest ch 37 ant 5 -55 -41.43 -25 Pass 00:05.924
51 ReaderBLEtest ch 37 ant 6 -55 -33.45 -25 Pass 00:05.992
52 ReaderBLEtest ch 37 ant 7 -55 -44.45 -25 Pass 00:05.934
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.385
55 ReaderBLEtest ch 38 ant 1 -55 -38.49 -25 Pass 00:05.907
56 ReaderBLEtest ch 38 ant 2 -55 -29.45 -25 Pass 00:05.914
57 ReaderBLEtest ch 38 ant 3 -55 -39.45 -25 Pass 00:05.947
58 ReaderBLEtest ch 38 ant 4 -55 -29.47 -25 Pass 00:05.918
59 ReaderBLEtest ch 38 ant 5 -55 -38.26 -25 Pass 00:05.924
60 ReaderBLEtest ch 38 ant 6 -55 -35.28 -25 Pass 00:05.965
61 ReaderBLEtest ch 38 ant 7 -55 -35.45 -25 Pass 00:05.928
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.375
64 ReaderBLEtest ch 39 ant 1 -55 -38.45 -25 Pass 00:05.939
65 ReaderBLEtest ch 39 ant 2 -55 -37.33 -25 Pass 00:05.932
66 ReaderBLEtest ch 39 ant 3 -55 -41.31 -25 Pass 00:05.973
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.939
68 ReaderBLEtest ch 39 ant 5 -55 -35.45 -25 Pass 00:05.939
69 ReaderBLEtest ch 39 ant 6 -55 -31.73 -25 Pass 00:05.936
70 ReaderBLEtest ch 39 ant 7 -55 -33.14 -25 Pass 00:05.967
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.345
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.000
Back to List