GuiSession


stationCode
ReaderEOL_03
scandData
000005853,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 15:04:15
endTime
11/12/2024 15:08:42
Duration
04:27.102
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.251
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.308
5 ReaderReset Pass Pass 00:00.108
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.311
8 Reader Get Serial Number 000005853 Pass 00:00.109
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39002BD Pass 00:00.220
11 SendReaderConfigFile Pass Pass 00:07.086
12 Get Main CPU version 2.1.1+1029 Pass 00:00.103
13 Get TX CPU version 0.15 Pass 00:00.103
14 Get BLE0 CPU version 0.10 Pass 00:00.108
15 Get BLE1 CPU version 0.10 Pass 00:00.108
16 Get BLE2 CPU version 0.10 Pass 00:00.101
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.769
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.102
21 ReaderTxGetTemp 31.37 Pass 00:00.107
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.437
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.314
26 Reader SyncTime Pass Pass 00:00.630
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.413
29 Get Last Spectrum Mesurment Amp 25 29.96 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.300
32 Reader SyncTime Pass Pass 00:00.619
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000910.14 928004000 Pass 00:00.378
35 Get Last Spectrum Mesurment Amp 25 28.45 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.410
38 Reader SyncTime Pass Pass 00:00.613
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700596.70 865704000 Pass 00:00.404
41 Get Last Spectrum Mesurment Amp 20 27.13 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.305
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.372
46 ReaderBLEtest ch 37 ant 1 -55 -41.21 -25 Pass 00:05.941
47 ReaderBLEtest ch 37 ant 2 -55 -39.78 -25 Pass 00:05.946
48 ReaderBLEtest ch 37 ant 3 -55 -42.43 -25 Pass 00:05.935
49 ReaderBLEtest ch 37 ant 4 -55 -33.49 -25 Pass 00:05.896
50 ReaderBLEtest ch 37 ant 5 -55 -39.45 -25 Pass 00:05.937
51 ReaderBLEtest ch 37 ant 6 -55 -32.43 -25 Pass 00:05.936
52 ReaderBLEtest ch 37 ant 7 -55 -42.45 -25 Pass 00:05.944
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.405
55 ReaderBLEtest ch 38 ant 1 -55 -39.45 -25 Pass 00:05.894
56 ReaderBLEtest ch 38 ant 2 -55 -30.27 -25 Pass 00:05.974
57 ReaderBLEtest ch 38 ant 3 -55 -40.79 -25 Pass 00:05.978
58 ReaderBLEtest ch 38 ant 4 -55 -30.28 -25 Pass 00:06.017
59 ReaderBLEtest ch 38 ant 5 -55 -39.45 -25 Pass 00:05.990
60 ReaderBLEtest ch 38 ant 6 -55 -36.45 -25 Pass 00:05.910
61 ReaderBLEtest ch 38 ant 7 -55 -36.45 -25 Pass 00:05.932
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.393
64 ReaderBLEtest ch 39 ant 1 -55 -37.76 -25 Pass 00:08.045
65 ReaderBLEtest ch 39 ant 2 -55 -36.45 -25 Pass 00:05.928
66 ReaderBLEtest ch 39 ant 3 -55 -41.43 -25 Pass 00:05.905
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.933
68 ReaderBLEtest ch 39 ant 5 -55 -35.45 -25 Pass 00:05.957
69 ReaderBLEtest ch 39 ant 6 -55 -31.55 -25 Pass 00:05.962
70 ReaderBLEtest ch 39 ant 7 -55 -32.45 -25 Pass 00:06.000
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.362
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.000
Back to List