GuiSession


stationCode
ReaderEOL_03
scandData
000006196,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 14:31:28
endTime
11/12/2024 14:35:51
Duration
04:23.222
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.255
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.103 Pass 00:00.321
5 ReaderReset Pass Pass 00:00.110
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.103 Pass 00:00.311
8 Reader Get Serial Number 000006196 Pass 00:00.102
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A3900225 Pass 00:00.215
11 SendReaderConfigFile Pass Pass 00:07.306
12 Get Main CPU version 2.1.1+1029 Pass 00:00.107
13 Get TX CPU version 0.15 Pass 00:00.107
14 Get BLE0 CPU version 0.10 Pass 00:00.102
15 Get BLE1 CPU version 0.10 Pass 00:00.100
16 Get BLE2 CPU version 0.10 Pass 00:00.105
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.719
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.101
21 ReaderTxGetTemp 30.25 Pass 00:00.104
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.431
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.318
26 Reader SyncTime Pass Pass 00:00.638
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865701071.19 865704000 Pass 00:00.400
29 Get Last Spectrum Mesurment Amp 25 29.79 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.314
32 Reader SyncTime Pass Pass 00:00.623
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928001147.39 928004000 Pass 00:00.397
35 Get Last Spectrum Mesurment Amp 25 28.92 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.414
38 Reader SyncTime Pass Pass 00:00.630
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.387
41 Get Last Spectrum Mesurment Amp 20 27.13 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.304
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.408
46 ReaderBLEtest ch 37 ant 1 -55 -42.45 -25 Pass 00:05.974
47 ReaderBLEtest ch 37 ant 2 -55 -41.45 -25 Pass 00:05.943
48 ReaderBLEtest ch 37 ant 3 -55 -43.45 -25 Pass 00:05.931
49 ReaderBLEtest ch 37 ant 4 -55 -34.45 -25 Pass 00:05.983
50 ReaderBLEtest ch 37 ant 5 -55 -40.49 -25 Pass 00:05.983
51 ReaderBLEtest ch 37 ant 6 -55 -33.48 -25 Pass 00:05.967
52 ReaderBLEtest ch 37 ant 7 -55 -42.95 -25 Pass 00:05.969
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.399
55 ReaderBLEtest ch 38 ant 1 -55 -39.43 -25 Pass 00:05.924
56 ReaderBLEtest ch 38 ant 2 -55 -30.38 -25 Pass 00:05.923
57 ReaderBLEtest ch 38 ant 3 -55 -40.45 -25 Pass 00:05.948
58 ReaderBLEtest ch 38 ant 4 -55 -30.45 -25 Pass 00:05.968
59 ReaderBLEtest ch 38 ant 5 -55 -38.45 -25 Pass 00:05.905
60 ReaderBLEtest ch 38 ant 6 -55 -35.65 -25 Pass 00:05.945
61 ReaderBLEtest ch 38 ant 7 -55 -36.45 -25 Pass 00:05.977
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.398
64 ReaderBLEtest ch 39 ant 1 -55 -37.45 -25 Pass 00:05.887
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.960
66 ReaderBLEtest ch 39 ant 3 -55 -42.11 -25 Pass 00:05.959
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.942
68 ReaderBLEtest ch 39 ant 5 -55 -35.30 -25 Pass 00:05.966
69 ReaderBLEtest ch 39 ant 6 -55 -31.45 -25 Pass 00:05.935
70 ReaderBLEtest ch 39 ant 7 -55 -32.45 -25 Pass 00:05.916
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.443
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.001
Back to List