GuiSession


stationCode
ReaderEOL_03
scandData
000006265,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 13:40:40
endTime
11/12/2024 13:45:02
Duration
04:21.784
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.265
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.311
5 ReaderReset Pass Pass 00:00.101
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.313
8 Reader Get Serial Number 000006265 Pass 00:00.101
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39001E2 Pass 00:00.215
11 SendReaderConfigFile Pass Pass 00:07.746
12 Get Main CPU version 2.1.1+1029 Pass 00:00.105
13 Get TX CPU version 0.15 Pass 00:00.107
14 Get BLE0 CPU version 0.10 Pass 00:00.100
15 Get BLE1 CPU version 0.10 Pass 00:00.103
16 Get BLE2 CPU version 0.10 Pass 00:00.108
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.739
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.105
21 ReaderTxGetTemp 38.12 Pass 00:00.107
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.438
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.308
26 Reader SyncTime Pass Pass 00:00.614
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700359.45 865704000 Pass 00:00.398
29 Get Last Spectrum Mesurment Amp 25 29.25 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.310
32 Reader SyncTime Pass Pass 00:00.611
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000435.65 928004000 Pass 00:00.379
35 Get Last Spectrum Mesurment Amp 25 29.96 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.412
38 Reader SyncTime Pass Pass 00:00.619
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700359.45 865704000 Pass 00:00.389
41 Get Last Spectrum Mesurment Amp 20 26.47 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.305
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.395
46 ReaderBLEtest ch 37 ant 1 -55 -40.35 -25 Pass 00:05.942
47 ReaderBLEtest ch 37 ant 2 -55 -38.92 -25 Pass 00:05.934
48 ReaderBLEtest ch 37 ant 3 -55 -41.45 -25 Pass 00:05.936
49 ReaderBLEtest ch 37 ant 4 -55 -33.13 -25 Pass 00:05.945
50 ReaderBLEtest ch 37 ant 5 -55 -38.45 -25 Pass 00:05.937
51 ReaderBLEtest ch 37 ant 6 -55 -32.14 -25 Pass 00:05.986
52 ReaderBLEtest ch 37 ant 7 -55 -41.45 -25 Pass 00:05.936
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.404
55 ReaderBLEtest ch 38 ant 1 -55 -38.43 -25 Pass 00:05.934
56 ReaderBLEtest ch 38 ant 2 -55 -29.68 -25 Pass 00:05.928
57 ReaderBLEtest ch 38 ant 3 -55 -40.03 -25 Pass 00:05.933
58 ReaderBLEtest ch 38 ant 4 -55 -31.21 -25 Pass 00:05.934
59 ReaderBLEtest ch 38 ant 5 -55 -38.44 -25 Pass 00:05.950
60 ReaderBLEtest ch 38 ant 6 -55 -35.47 -25 Pass 00:05.967
61 ReaderBLEtest ch 38 ant 7 -55 -35.45 -25 Pass 00:05.940
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.350
64 ReaderBLEtest ch 39 ant 1 -55 -38.38 -25 Pass 00:05.963
65 ReaderBLEtest ch 39 ant 2 -55 -37.43 -25 Pass 00:05.913
66 ReaderBLEtest ch 39 ant 3 -55 -41.45 -25 Pass 00:05.929
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.924
68 ReaderBLEtest ch 39 ant 5 -55 -36.45 -25 Pass 00:05.961
69 ReaderBLEtest ch 39 ant 6 -55 -33.40 -25 Pass 00:05.946
70 ReaderBLEtest ch 39 ant 7 -55 -33.45 -25 Pass 00:05.965
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.368
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.000
Back to List