GuiSession


stationCode
ReaderEOL_03
scandData
000005857,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 13:13:09
endTime
11/12/2024 13:17:28
Duration
04:19.056
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.269
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.103 Pass 00:00.317
5 ReaderReset Pass Pass 00:00.110
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.103 Pass 00:00.314
8 Reader Get Serial Number 000005857 Pass 00:00.110
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39002B9 Pass 00:00.213
11 SendReaderConfigFile Pass Pass 00:07.557
12 Get Main CPU version 2.1.1+1029 Pass 00:00.104
13 Get TX CPU version 0.15 Pass 00:00.102
14 Get BLE0 CPU version 0.10 Pass 00:00.105
15 Get BLE1 CPU version 0.10 Pass 00:00.100
16 Get BLE2 CPU version 0.10 Pass 00:00.101
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.732
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.105
21 ReaderTxGetTemp 30.5 Pass 00:00.107
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.413
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.306
26 Reader SyncTime Pass Pass 00:00.608
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865701308.44 865704000 Pass 00:00.397
29 Get Last Spectrum Mesurment Amp 25 29.50 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.315
32 Reader SyncTime Pass Pass 00:00.618
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928001384.64 928004000 Pass 00:00.379
35 Get Last Spectrum Mesurment Amp 25 29.64 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.411
38 Reader SyncTime Pass Pass 00:00.628
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865701308.44 865704000 Pass 00:00.408
41 Get Last Spectrum Mesurment Amp 20 26.71 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.319
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.403
46 ReaderBLEtest ch 37 ant 1 -55 -42.45 -25 Pass 00:05.969
47 ReaderBLEtest ch 37 ant 2 -55 -40.45 -25 Pass 00:05.919
48 ReaderBLEtest ch 37 ant 3 -55 -42.53 -25 Pass 00:05.898
49 ReaderBLEtest ch 37 ant 4 -55 -33.45 -25 Pass 00:05.950
50 ReaderBLEtest ch 37 ant 5 -55 -39.45 -25 Pass 00:05.988
51 ReaderBLEtest ch 37 ant 6 -55 -32.53 -25 Pass 00:05.946
52 ReaderBLEtest ch 37 ant 7 -55 -41.75 -25 Pass 00:05.929
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.405
55 ReaderBLEtest ch 38 ant 1 -55 -40.45 -25 Pass 00:05.966
56 ReaderBLEtest ch 38 ant 2 -55 -30.45 -25 Pass 00:05.931
57 ReaderBLEtest ch 38 ant 3 -55 -39.24 -25 Pass 00:05.942
58 ReaderBLEtest ch 38 ant 4 -55 -31.45 -25 Pass 00:05.956
59 ReaderBLEtest ch 38 ant 5 -55 -38.45 -25 Pass 00:05.898
60 ReaderBLEtest ch 38 ant 6 -55 -36.33 -25 Pass 00:05.982
61 ReaderBLEtest ch 38 ant 7 -55 -37.45 -25 Pass 00:06.006
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.392
64 ReaderBLEtest ch 39 ant 1 -55 -36.45 -25 Pass 00:05.990
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.965
66 ReaderBLEtest ch 39 ant 3 -55 -42.42 -25 Pass 00:06.000
67 ReaderBLEtest ch 39 ant 4 -55 -37.45 -25 Pass 00:05.946
68 ReaderBLEtest ch 39 ant 5 -55 -34.45 -25 Pass 00:05.935
69 ReaderBLEtest ch 39 ant 6 -55 -31.43 -25 Pass 00:06.033
70 ReaderBLEtest ch 39 ant 7 -55 -32.53 -25 Pass 00:05.954
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.345
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.001
Back to List