GuiSession


stationCode
ReaderEOL_03
scandData
000005884,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 13:07:45
endTime
11/12/2024 13:12:05
Duration
04:19.088
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.263
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.306
5 ReaderReset Pass Pass 00:00.103
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.317
8 Reader Get Serial Number 000005884 Pass 00:00.107
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39002A0 Pass 00:00.212
11 SendReaderConfigFile Pass Pass 00:08.324
12 Get Main CPU version 2.1.1+1029 Pass 00:00.108
13 Get TX CPU version 0.15 Pass 00:00.104
14 Get BLE0 CPU version 0.10 Pass 00:00.107
15 Get BLE1 CPU version 0.10 Pass 00:00.103
16 Get BLE2 CPU version 0.10 Pass 00:00.105
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.663
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.108
21 ReaderTxGetTemp 32.12 Pass 00:00.105
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.429
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.318
26 Reader SyncTime Pass Pass 00:00.628
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865701071.19 865704000 Pass 00:00.402
29 Get Last Spectrum Mesurment Amp 25 27.67 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.310
32 Reader SyncTime Pass Pass 00:00.623
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928001384.64 928004000 Pass 00:00.382
35 Get Last Spectrum Mesurment Amp 25 30.46 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.424
38 Reader SyncTime Pass Pass 00:00.614
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865701071.19 865704000 Pass 00:00.408
41 Get Last Spectrum Mesurment Amp 20 26.01 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.315
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.405
46 ReaderBLEtest ch 37 ant 1 -55 -40.49 -25 Pass 00:05.955
47 ReaderBLEtest ch 37 ant 2 -55 -38.45 -25 Pass 00:05.928
48 ReaderBLEtest ch 37 ant 3 -55 -41.45 -25 Pass 00:05.906
49 ReaderBLEtest ch 37 ant 4 -55 -33.39 -25 Pass 00:05.972
50 ReaderBLEtest ch 37 ant 5 -55 -39.45 -25 Pass 00:06.018
51 ReaderBLEtest ch 37 ant 6 -55 -32.00 -25 Pass 00:05.929
52 ReaderBLEtest ch 37 ant 7 -55 -42.43 -25 Pass 00:05.914
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.403
55 ReaderBLEtest ch 38 ant 1 -55 -39.43 -25 Pass 00:05.911
56 ReaderBLEtest ch 38 ant 2 -55 -30.45 -25 Pass 00:05.947
57 ReaderBLEtest ch 38 ant 3 -55 -42.21 -25 Pass 00:05.934
58 ReaderBLEtest ch 38 ant 4 -55 -31.45 -25 Pass 00:05.932
59 ReaderBLEtest ch 38 ant 5 -55 -38.45 -25 Pass 00:05.934
60 ReaderBLEtest ch 38 ant 6 -55 -35.45 -25 Pass 00:05.992
61 ReaderBLEtest ch 38 ant 7 -55 -36.65 -25 Pass 00:05.945
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.358
64 ReaderBLEtest ch 39 ant 1 -55 -38.00 -25 Pass 00:05.946
65 ReaderBLEtest ch 39 ant 2 -55 -35.35 -25 Pass 00:05.899
66 ReaderBLEtest ch 39 ant 3 -55 -41.53 -25 Pass 00:05.951
67 ReaderBLEtest ch 39 ant 4 -55 -37.45 -25 Pass 00:05.893
68 ReaderBLEtest ch 39 ant 5 -55 -35.38 -25 Pass 00:05.983
69 ReaderBLEtest ch 39 ant 6 -55 -32.13 -25 Pass 00:05.908
70 ReaderBLEtest ch 39 ant 7 -55 -32.47 -25 Pass 00:05.943
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.322
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.000