GuiSession


stationCode
ReaderEOL_03
scandData
000005856,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 12:56:15
endTime
11/12/2024 13:00:37
Duration
04:22.518
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.292
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.100 Pass 00:00.308
5 ReaderReset Pass Pass 00:00.109
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.100 Pass 00:03.964
8 Reader Get Serial Number 000005856 Pass 00:00.103
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39002BA Pass 00:00.213
11 SendReaderConfigFile Pass Pass 00:08.768
12 Get Main CPU version 2.1.1+1029 Pass 00:00.109
13 Get TX CPU version 0.15 Pass 00:00.104
14 Get BLE0 CPU version 0.10 Pass 00:00.103
15 Get BLE1 CPU version 0.10 Pass 00:00.101
16 Get BLE2 CPU version 0.10 Pass 00:00.108
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.635
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.108
21 ReaderTxGetTemp 35.5 Pass 00:00.101
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.417
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.312
26 Reader SyncTime Pass Pass 00:00.619
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700596.70 865704000 Pass 00:00.398
29 Get Last Spectrum Mesurment Amp 25 27.86 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.308
32 Reader SyncTime Pass Pass 00:00.624
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000672.89 928004000 Pass 00:00.383
35 Get Last Spectrum Mesurment Amp 25 29.79 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.414
38 Reader SyncTime Pass Pass 00:00.618
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700596.70 865704000 Pass 00:00.396
41 Get Last Spectrum Mesurment Amp 20 26.03 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.315
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.411
46 ReaderBLEtest ch 37 ant 1 -55 -40.45 -25 Pass 00:05.991
47 ReaderBLEtest ch 37 ant 2 -55 -39.45 -25 Pass 00:05.897
48 ReaderBLEtest ch 37 ant 3 -55 -41.45 -25 Pass 00:05.941
49 ReaderBLEtest ch 37 ant 4 -55 -32.47 -25 Pass 00:05.970
50 ReaderBLEtest ch 37 ant 5 -55 -38.55 -25 Pass 00:05.966
51 ReaderBLEtest ch 37 ant 6 -55 -31.81 -25 Pass 00:05.924
52 ReaderBLEtest ch 37 ant 7 -55 -40.45 -25 Pass 00:05.936
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.429
55 ReaderBLEtest ch 38 ant 1 -55 -42.51 -25 Pass 00:05.975
56 ReaderBLEtest ch 38 ant 2 -55 -31.45 -25 Pass 00:05.951
57 ReaderBLEtest ch 38 ant 3 -55 -41.45 -25 Pass 00:05.934
58 ReaderBLEtest ch 38 ant 4 -55 -32.40 -25 Pass 00:05.961
59 ReaderBLEtest ch 38 ant 5 -55 -39.45 -25 Pass 00:05.933
60 ReaderBLEtest ch 38 ant 6 -55 -37.45 -25 Pass 00:05.996
61 ReaderBLEtest ch 38 ant 7 -55 -37.55 -25 Pass 00:05.949
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.365
64 ReaderBLEtest ch 39 ant 1 -55 -37.45 -25 Pass 00:05.901
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.984
66 ReaderBLEtest ch 39 ant 3 -55 -41.45 -25 Pass 00:05.950
67 ReaderBLEtest ch 39 ant 4 -55 -37.45 -25 Pass 00:05.889
68 ReaderBLEtest ch 39 ant 5 -55 -34.45 -25 Pass 00:05.972
69 ReaderBLEtest ch 39 ant 6 -55 -31.45 -25 Pass 00:05.938
70 ReaderBLEtest ch 39 ant 7 -55 -31.62 -25 Pass 00:05.957
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.408
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.011
Back to List