GuiSession


stationCode
ReaderEOL_03
scandData
000006175,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 11:28:14
endTime
11/12/2024 11:32:30
Duration
04:16.169
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.263
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.312
5 ReaderReset Pass Pass 00:00.110
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.318
8 Reader Get Serial Number 000006175 Pass 00:00.103
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A390023A Pass 00:00.220
11 SendReaderConfigFile Pass Pass 00:07.903
12 Get Main CPU version 2.1.1+1029 Pass 00:00.108
13 Get TX CPU version 0.15 Pass 00:00.109
14 Get BLE0 CPU version 0.10 Pass 00:00.104
15 Get BLE1 CPU version 0.10 Pass 00:00.109
16 Get BLE2 CPU version 0.10 Pass 00:00.109
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.788
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.101
21 ReaderTxGetTemp 33.25 Pass 00:00.106
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.418
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.301
26 Reader SyncTime Pass Pass 00:00.630
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865701071.19 865704000 Pass 00:00.404
29 Get Last Spectrum Mesurment Amp 25 29.16 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.305
32 Reader SyncTime Pass Pass 00:00.617
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928001147.39 928004000 Pass 00:00.380
35 Get Last Spectrum Mesurment Amp 25 29.33 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.410
38 Reader SyncTime Pass Pass 00:00.615
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865701071.19 865704000 Pass 00:00.410
41 Get Last Spectrum Mesurment Amp 20 26.98 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.302
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.355
46 ReaderBLEtest ch 37 ant 1 -55 -41.43 -25 Pass 00:05.952
47 ReaderBLEtest ch 37 ant 2 -55 -39.87 -25 Pass 00:05.980
48 ReaderBLEtest ch 37 ant 3 -55 -41.45 -25 Pass 00:05.948
49 ReaderBLEtest ch 37 ant 4 -55 -33.45 -25 Pass 00:05.931
50 ReaderBLEtest ch 37 ant 5 -55 -39.49 -25 Pass 00:05.954
51 ReaderBLEtest ch 37 ant 6 -55 -32.54 -25 Pass 00:05.943
52 ReaderBLEtest ch 37 ant 7 -55 -40.47 -25 Pass 00:05.949
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.398
55 ReaderBLEtest ch 38 ant 1 -55 -41.45 -25 Pass 00:05.933
56 ReaderBLEtest ch 38 ant 2 -55 -31.45 -25 Pass 00:05.953
57 ReaderBLEtest ch 38 ant 3 -55 -41.47 -25 Pass 00:05.978
58 ReaderBLEtest ch 38 ant 4 -55 -32.18 -25 Pass 00:05.981
59 ReaderBLEtest ch 38 ant 5 -55 -40.45 -25 Pass 00:06.000
60 ReaderBLEtest ch 38 ant 6 -55 -37.45 -25 Pass 00:05.948
61 ReaderBLEtest ch 38 ant 7 -55 -38.45 -25 Pass 00:05.917
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.376
64 ReaderBLEtest ch 39 ant 1 -55 -38.45 -25 Pass 00:05.956
65 ReaderBLEtest ch 39 ant 2 -55 -36.45 -25 Pass 00:05.937
66 ReaderBLEtest ch 39 ant 3 -55 -42.89 -25 Pass 00:05.940
67 ReaderBLEtest ch 39 ant 4 -55 -39.45 -25 Pass 00:05.930
68 ReaderBLEtest ch 39 ant 5 -55 -36.45 -25 Pass 00:05.950
69 ReaderBLEtest ch 39 ant 6 -55 -32.48 -25 Pass 00:05.933
70 ReaderBLEtest ch 39 ant 7 -55 -33.45 -25 Pass 00:05.945
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.438
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.001
Back to List