GuiSession


stationCode
ReaderEOL_03
scandData
000006216,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 11:04:01
endTime
11/12/2024 11:08:17
Duration
04:16.190
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.278
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.537
5 ReaderReset Pass Pass 00:00.114
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.102 Pass 00:00.310
8 Reader Get Serial Number 000006216 Pass 00:00.105
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A3900211 Pass 00:00.213
11 SendReaderConfigFile Pass Pass 00:08.578
12 Get Main CPU version 2.1.1+1029 Pass 00:00.107
13 Get TX CPU version 0.15 Pass 00:00.101
14 Get BLE0 CPU version 0.10 Pass 00:00.101
15 Get BLE1 CPU version 0.10 Pass 00:00.108
16 Get BLE2 CPU version 0.10 Pass 00:00.100
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.862
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.107
21 ReaderTxGetTemp 33.25 Pass 00:00.109
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.423
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.319
26 Reader SyncTime Pass Pass 00:00.636
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.412
29 Get Last Spectrum Mesurment Amp 25 29.46 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.308
32 Reader SyncTime Pass Pass 00:00.614
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000910.14 928004000 Pass 00:00.399
35 Get Last Spectrum Mesurment Amp 25 28.13 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.418
38 Reader SyncTime Pass Pass 00:00.622
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.405
41 Get Last Spectrum Mesurment Amp 20 27.17 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.318
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.418
46 ReaderBLEtest ch 37 ant 1 -55 -41.45 -25 Pass 00:05.955
47 ReaderBLEtest ch 37 ant 2 -55 -39.43 -25 Pass 00:05.921
48 ReaderBLEtest ch 37 ant 3 -55 -41.59 -25 Pass 00:05.972
49 ReaderBLEtest ch 37 ant 4 -55 -33.45 -25 Pass 00:05.958
50 ReaderBLEtest ch 37 ant 5 -55 -39.38 -25 Pass 00:05.935
51 ReaderBLEtest ch 37 ant 6 -55 -32.19 -25 Pass 00:05.924
52 ReaderBLEtest ch 37 ant 7 -55 -42.45 -25 Pass 00:05.963
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.382
55 ReaderBLEtest ch 38 ant 1 -55 -40.40 -25 Pass 00:05.993
56 ReaderBLEtest ch 38 ant 2 -55 -31.43 -25 Pass 00:05.929
57 ReaderBLEtest ch 38 ant 3 -55 -40.81 -25 Pass 00:05.932
58 ReaderBLEtest ch 38 ant 4 -55 -32.45 -25 Pass 00:05.960
59 ReaderBLEtest ch 38 ant 5 -55 -38.45 -25 Pass 00:05.971
60 ReaderBLEtest ch 38 ant 6 -55 -36.43 -25 Pass 00:05.958
61 ReaderBLEtest ch 38 ant 7 -55 -37.47 -25 Pass 00:05.915
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.380
64 ReaderBLEtest ch 39 ant 1 -55 -38.45 -25 Pass 00:05.887
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.953
66 ReaderBLEtest ch 39 ant 3 -55 -41.42 -25 Pass 00:05.983
67 ReaderBLEtest ch 39 ant 4 -55 -38.38 -25 Pass 00:05.933
68 ReaderBLEtest ch 39 ant 5 -55 -34.45 -25 Pass 00:05.924
69 ReaderBLEtest ch 39 ant 6 -55 -32.57 -25 Pass 00:05.923
70 ReaderBLEtest ch 39 ant 7 -55 -33.40 -25 Pass 00:05.976
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.474
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.001
Back to List