GuiSession


stationCode
ReaderEOL_03
scandData
000006261,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 10:56:10
endTime
11/12/2024 11:00:26
Duration
04:16.170
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.330
2 ReaderTypeSelect HB Pass 00:00.001
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.315
5 ReaderReset Pass Pass 00:00.105
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.307
8 Reader Get Serial Number 000006261 Pass 00:00.110
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39001E6 Pass 00:00.220
11 SendReaderConfigFile Pass Pass 00:08.568
12 Get Main CPU version 2.1.1+1029 Pass 00:00.108
13 Get TX CPU version 0.15 Pass 00:00.101
14 Get BLE0 CPU version 0.10 Pass 00:00.101
15 Get BLE1 CPU version 0.10 Pass 00:00.108
16 Get BLE2 CPU version 0.10 Pass 00:00.106
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.796
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.102
21 ReaderTxGetTemp 39.12 Pass 00:00.103
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.421
24 SetSpectrum 865700000 Pass Pass 00:00.001
25 Set Reader TX freq 865700 Pass Pass 00:00.306
26 Reader SyncTime Pass Pass 00:00.609
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700122.20 865704000 Pass 00:00.445
29 Get Last Spectrum Mesurment Amp 25 29.67 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.304
32 Reader SyncTime Pass Pass 00:00.615
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000198.40 928004000 Pass 00:00.406
35 Get Last Spectrum Mesurment Amp 25 29.92 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.429
38 Reader SyncTime Pass Pass 00:00.619
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700122.20 865704000 Pass 00:00.407
41 Get Last Spectrum Mesurment Amp 20 27.01 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.308
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.356
46 ReaderBLEtest ch 37 ant 1 -55 -45.14 -25 Pass 00:05.955
47 ReaderBLEtest ch 37 ant 2 -55 -40.40 -25 Pass 00:05.945
48 ReaderBLEtest ch 37 ant 3 -55 -42.53 -25 Pass 00:05.962
49 ReaderBLEtest ch 37 ant 4 -55 -34.45 -25 Pass 00:05.961
50 ReaderBLEtest ch 37 ant 5 -55 -40.45 -25 Pass 00:05.905
51 ReaderBLEtest ch 37 ant 6 -55 -33.02 -25 Pass 00:05.958
52 ReaderBLEtest ch 37 ant 7 -55 -44.43 -25 Pass 00:05.941
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.378
55 ReaderBLEtest ch 38 ant 1 -55 -41.21 -25 Pass 00:05.998
56 ReaderBLEtest ch 38 ant 2 -55 -31.45 -25 Pass 00:05.956
57 ReaderBLEtest ch 38 ant 3 -55 -42.45 -25 Pass 00:05.934
58 ReaderBLEtest ch 38 ant 4 -55 -32.92 -25 Pass 00:05.896
59 ReaderBLEtest ch 38 ant 5 -55 -39.43 -25 Pass 00:05.974
60 ReaderBLEtest ch 38 ant 6 -55 -37.45 -25 Pass 00:05.986
61 ReaderBLEtest ch 38 ant 7 -55 -40.09 -25 Pass 00:05.929
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.386
64 ReaderBLEtest ch 39 ant 1 -55 -38.43 -25 Pass 00:05.954
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.974
66 ReaderBLEtest ch 39 ant 3 -55 -41.45 -25 Pass 00:05.928
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.941
68 ReaderBLEtest ch 39 ant 5 -55 -34.45 -25 Pass 00:05.944
69 ReaderBLEtest ch 39 ant 6 -55 -32.64 -25 Pass 00:05.945
70 ReaderBLEtest ch 39 ant 7 -55 -33.45 -25 Pass 00:05.931
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.717
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.002
Back to List