GuiSession


stationCode
ReaderEOL_03
scandData
000006265,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 10:13:53
endTime
11/12/2024 10:18:38
Duration
04:45.149
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.298
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.101 Pass 00:00.349
5 ReaderReset Pass Pass 00:00.107
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.101 Pass 00:04.003
8 Reader Get Serial Number 000006265 Pass 00:00.106
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39001E2 Pass 00:00.231
11 SendReaderConfigFile Pass Pass 00:07.124
12 Get Main CPU version 2.1.1+1029 Pass 00:00.108
13 Get TX CPU version 0.15 Pass 00:00.103
14 Get BLE0 CPU version 0.10 Pass 00:00.101
15 Get BLE1 CPU version 0.10 Pass 00:00.100
16 Get BLE2 CPU version 0.10 Pass 00:00.100
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.810
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.102
21 ReaderTxGetTemp 35.75 Pass 00:00.103
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.449
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.315
26 Reader SyncTime Pass Pass 00:00.612
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700359.45 865704000 Pass 00:00.405
29 Get Last Spectrum Mesurment Amp 25 29.18 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.309
32 Reader SyncTime Pass Pass 00:00.630
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000435.65 928004000 Pass 00:00.393
35 Get Last Spectrum Mesurment Amp 25 30.49 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.417
38 Reader SyncTime Pass Pass 00:00.615
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700359.45 865704000 Pass 00:00.417
41 Get Last Spectrum Mesurment Amp 20 26.41 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.307
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.394
46 ReaderBLEtest ch 37 ant 1 -55 -40.79 -25 Pass 00:05.976
47 ReaderBLEtest ch 37 ant 2 -55 -38.45 -25 Pass 00:05.982
48 ReaderBLEtest ch 37 ant 3 -55 -41.45 -25 Pass 00:06.030
49 ReaderBLEtest ch 37 ant 4 -55 -33.41 -25 Pass 00:05.981
50 ReaderBLEtest ch 37 ant 5 -55 -38.45 -25 Pass 00:05.911
51 ReaderBLEtest ch 37 ant 6 -55 -32.06 -25 Pass 00:05.978
52 ReaderBLEtest ch 37 ant 7 -55 -40.90 -25 Pass 00:05.962
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.404
55 ReaderBLEtest ch 38 ant 1 -55 -37.45 -25 Pass 00:05.920
56 ReaderBLEtest ch 38 ant 2 -55 -30.09 -25 Pass 00:05.943
57 ReaderBLEtest ch 38 ant 3 -55 -40.45 -25 Pass 00:06.017
58 ReaderBLEtest ch 38 ant 4 -55 -30.93 -25 Pass 00:05.966
59 ReaderBLEtest ch 38 ant 5 -55 -38.51 -25 Pass 00:05.970
60 ReaderBLEtest ch 38 ant 6 -55 -35.43 -25 Pass 00:05.902
61 ReaderBLEtest ch 38 ant 7 -55 -36.45 -25 Pass 00:05.943
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.357
64 ReaderBLEtest ch 39 ant 1 -55 -37.49 -25 Pass 00:05.952
65 ReaderBLEtest ch 39 ant 2 -55 -36.47 -25 Pass 00:05.963
66 ReaderBLEtest ch 39 ant 3 -55 -42.45 -25 Pass 00:05.961
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.996
68 ReaderBLEtest ch 39 ant 5 -55 -36.45 -25 Pass 00:05.983
69 ReaderBLEtest ch 39 ant 6 -55 -33.45 -25 Pass 00:05.996
70 ReaderBLEtest ch 39 ant 7 -55 -33.31 -25 Pass 00:05.995
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:01.389
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.000
Back to List