GuiSession


stationCode
ReaderEOL_03
scandData
000006196,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/12/2024 10:06:12
endTime
11/12/2024 10:10:55
Duration
04:43.523
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.356
2 ReaderTypeSelect HB Pass 00:00.001
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.100 Pass 00:00.734
5 ReaderReset Pass Pass 00:00.105
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.100 Pass 00:00.327
8 Reader Get Serial Number 000006196 Pass 00:00.108
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A3900225 Pass 00:00.219
11 SendReaderConfigFile Pass Pass 00:08.564
12 Get Main CPU version 2.1.1+1029 Pass 00:00.109
13 Get TX CPU version 0.15 Pass 00:00.108
14 Get BLE0 CPU version 0.10 Pass 00:00.102
15 Get BLE1 CPU version 0.10 Pass 00:00.107
16 Get BLE2 CPU version 0.10 Pass 00:00.106
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.815
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.120
21 ReaderTxGetTemp 34.75 Pass 00:00.102
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.418
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.316
26 Reader SyncTime Pass Pass 00:00.613
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865700359.45 865704000 Pass 00:00.401
29 Get Last Spectrum Mesurment Amp 25 29.25 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.311
32 Reader SyncTime Pass Pass 00:00.617
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928000435.65 928004000 Pass 00:00.409
35 Get Last Spectrum Mesurment Amp 25 29.66 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.425
38 Reader SyncTime Pass Pass 00:00.625
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700359.45 865704000 Pass 00:00.393
41 Get Last Spectrum Mesurment Amp 20 26.56 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.309
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.382
46 ReaderBLEtest ch 37 ant 1 -55 -43.30 -25 Pass 00:05.989
47 ReaderBLEtest ch 37 ant 2 -55 -41.38 -25 Pass 00:06.010
48 ReaderBLEtest ch 37 ant 3 -55 -42.81 -25 Pass 00:08.084
49 ReaderBLEtest ch 37 ant 4 -55 -34.45 -25 Pass 00:05.984
50 ReaderBLEtest ch 37 ant 5 -55 -41.40 -25 Pass 00:05.936
51 ReaderBLEtest ch 37 ant 6 -55 -33.49 -25 Pass 00:05.948
52 ReaderBLEtest ch 37 ant 7 -55 -42.76 -25 Pass 00:05.999
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.366
55 ReaderBLEtest ch 38 ant 1 -55 -38.45 -25 Pass 00:05.946
56 ReaderBLEtest ch 38 ant 2 -55 -30.45 -25 Pass 00:05.989
57 ReaderBLEtest ch 38 ant 3 -55 -41.45 -25 Pass 00:05.957
58 ReaderBLEtest ch 38 ant 4 -55 -30.45 -25 Pass 00:05.917
59 ReaderBLEtest ch 38 ant 5 -55 -38.45 -25 Pass 00:05.959
60 ReaderBLEtest ch 38 ant 6 -55 -35.45 -25 Pass 00:05.958
61 ReaderBLEtest ch 38 ant 7 -55 -36.98 -25 Pass 00:05.958
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.398
64 ReaderBLEtest ch 39 ant 1 -55 -37.45 -25 Pass 00:05.927
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.978
66 ReaderBLEtest ch 39 ant 3 -55 -42.81 -25 Pass 00:05.912
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:05.953
68 ReaderBLEtest ch 39 ant 5 -55 -35.45 -25 Pass 00:05.999
69 ReaderBLEtest ch 39 ant 6 -55 -31.72 -25 Pass 00:05.963
70 ReaderBLEtest ch 39 ant 7 -55 -32.75 -25 Pass 00:05.960
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:02.518
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.001
Back to List