GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_SKIP_CAL_20241112_114644
startTime
11/12/2024 09:47:00
endTime
11/12/2024 09:48:13
Duration
01:12.746
Status
Fail

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.758
2 Reader PWR reset Pass 00:00.000
3 Turn OFF the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.025
4 Release NXP reset line Pass Pass 00:00.023
5 Release all pinout Pass Pass 00:00.035
6 Turn ON the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.035
7 Delay 6000 Pass Pass 00:06.000
8 Reader Connect Pass 00:00.000
9 ConnectToReaderTelnet 192.168.0.151 Pass 00:00.312
10 ReaderSetSerialNumber 000005331 Pass 00:00.317
11 ReaderSetMacAddress 1063A39000EB Pass 00:00.356
12 Restart Reader Pass Pass 00:00.106
13 Delay 6000 Pass Pass 00:06.000
14 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.315
15 ReaderGetMacAddress 1063A39000EB Pass 00:00.223
16 SendReaderConfigFile Pass Pass 00:08.983
17 Get Main CPU version 2.1.1+1029 Pass 00:00.114
18 Get TX CPU version 0.15 Pass 00:00.724
19 Get BLE0 CPU version 0.10 Pass 00:00.112
20 Get BLE1 CPU version 0.10 Pass 00:00.727
21 Get BLE2 CPU version 0.10 Pass 00:00.721
22 Start TX (warming up) Pass 00:00.000
23 TesterMCU_Set_ISM_Mux Pass Pass 00:00.030
24 Set TX on pwr = 240 freq = 902000 debug Pass Pass 00:01.680
25 Delay 10000 Pass Pass 00:10.000
26 TX Test Pass 00:00.000
27 SetSpectrum Pass Pass 00:00.002
28 Get Last Spectrum Mesurment Freq 902000618.38 Pass 00:00.487
29 Get Last Spectrum Mesurment Amp 20 29.16 100 Pass 00:00.000
30 Set TX on pwr = 240 freq = 928000 debug Pass Pass 00:01.695
31 SetSpectrum Pass Pass 00:00.000
32 Get Last Spectrum Mesurment Freq 928000619.10 Pass 00:00.480
33 Get Last Spectrum Mesurment Amp 29.25 Pass 00:00.000
34 Set TX on pwr = 240 freq = 865700 debug Pass Pass 00:01.685
35 SetSpectrum Pass Pass 00:00.000
36 Get Last Spectrum Mesurment Freq 865700498.74 Pass 00:00.512
37 Get Last Spectrum Mesurment Amp 28.20 Pass 00:00.000
38 TX Test - post calibration Pass 00:00.000
39 Restart Reader Pass Pass 00:00.107
40 Delay 6000 Pass Pass 00:06.000
41 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.433
42 SendReaderConfigFile Pass Pass 00:09.396
43 SetSpectrum Pass Pass 00:00.000
44 Set TX on 30 928000 open Pass Pass 00:01.685
45 Get Last Spectrum Mesurment Freq 928996000 928000619.10 928004000 Pass 00:00.469
46 Get Last Spectrum Mesurment Amp 28 28.92 32 Pass 00:00.000
47 SetSpectrum Pass Pass 00:00.000
48 Set TX on 30 915000 open Pass Pass 00:01.684
49 Get Last Spectrum Mesurment Freq 915000618.74 Pass 00:00.481
50 Get Last Spectrum Mesurment Amp 29.30 Pass 00:00.000
51 SetSpectrum Pass Pass 00:00.000
52 Set TX on 30 902000 open Pass Pass 00:01.676
53 Get Last Spectrum Mesurment Freq 902000618.38 Pass 00:00.484
54 Get Last Spectrum Mesurment Amp 28.76 Pass 00:00.000
55 SetSpectrum Pass Pass 00:00.000
56 Set TX on 30 865700 open Pass Pass 00:01.689
57 Get Last Spectrum Mesurment Freq 865796000 865700498.74 865704000 Pass 00:00.505
58 Get Last Spectrum Mesurment Amp 28 27.94 32 Fail 00:00.000
Back to List