GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_SKIP_CAL_20241112_114017
startTime
11/12/2024 09:40:49
endTime
11/12/2024 09:41:30
Duration
00:40.164
Status
Error

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.829
2 Reader PWR reset Pass 00:00.000
3 Turn OFF the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.026
4 Release NXP reset line Pass Pass 00:00.037
5 Release all pinout Pass Pass 00:00.034
6 Turn ON the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.035
7 Delay 6000 Pass Pass 00:06.000
8 Reader Connect Pass 00:00.000
9 ConnectToReaderTelnet 192.168.0.151 Pass 00:00.340
10 ReaderSetSerialNumber 000005331 Pass 00:00.322
11 ReaderSetMacAddress 1063A39000EB Pass 00:00.352
12 Restart Reader Pass Pass 00:00.110
13 Delay 6000 Pass Pass 00:06.000
14 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.490
15 ReaderGetMacAddress 1063A39000EB Pass 00:00.368
16 SendReaderConfigFile Pass Pass 00:09.190
17 Get Main CPU version 2.1.1+1029 Pass 00:00.116
18 Get TX CPU version 0.15 Pass 00:00.102
19 Get BLE0 CPU version 0.10 Pass 00:00.114
20 Get BLE1 CPU version 0.10 Pass 00:00.110
21 Get BLE2 CPU version 0.10 Pass 00:00.107
22 Start TX (warming up) Pass 00:00.000
23 TesterMCU_Set_ISM_Mux Pass Pass 00:00.035
24 Set TX on pwr = 240 freq = 902000 debug Pass Pass 00:01.685
25 Delay 10000 Pass Pass 00:10.000
26 TX Test Pass 00:00.000
27 SetSpectrum Missing parameter RF_path_station_loss Error 00:00.043
Back to List