GuiSession


stationCode
uXiterFT_01
scandData
000006117,AS000018REVC023324
ATPName
uXIter_FT_ATP_Full_20241112_093412
startTime
11/12/2024 07:56:49
endTime
11/12/2024 07:56:58
Duration
00:09.231
Status
Stop

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.913
2 OC :: 12V to 4V DCDC Pass 00:00.000
3 Turn ON 12V source Pass Pass 00:00.035
4 Enable 4V DCDC Pass Pass 00:00.024
5 Delay 1000 Pass Pass 00:01.000
6 Read DUT 4V voltage rail -uX1 3800 3959 4100 Pass 00:00.446
7 Measure the current over 12v current rail 67 Pass 00:00.444
8 CC :: 12V to 4V DCDC Pass 00:00.000
9 Load 4V rail with external resistor Pass Pass 00:00.028
10 Delay 1000 Pass Pass 00:01.000
Back to List