GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_SKIP_CAL_20241112_082030
startTime
11/12/2024 06:26:11
endTime
11/12/2024 06:27:19
Duration
01:08.079
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.765
2 Reader PWR reset Pass 00:00.000
3 Turn OFF the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.023
4 Release NXP reset line Pass Pass 00:00.026
5 Release all pinout Pass Pass 00:00.032
6 Turn ON the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.035
7 Delay 6000 Pass Pass 00:06.000
8 Reader Connect Pass 00:00.000
9 ConnectToReaderTelnet 192.168.0.151 Pass 00:00.361
10 ReaderSetSerialNumber 000005331 Pass 00:00.320
11 ReaderSetMacAddress 1063A39000EB Pass 00:00.224
12 Restart Reader Pass Pass 00:00.111
13 Delay 6000 Pass Pass 00:06.000
14 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.330
15 ReaderGetMacAddress 1063A39000EB Pass 00:00.211
16 SendReaderConfigFile Pass Pass 00:08.855
17 Get Main CPU version 2.1.1+1029 Pass 00:00.105
18 Get TX CPU version 0.15 Pass 00:00.713
19 Get BLE0 CPU version 0.10 Pass 00:00.722
20 Get BLE1 CPU version 0.10 Pass 00:00.719
21 Get BLE2 CPU version 0.10 Pass 00:00.106
22 Start TX (warming up) Pass 00:00.000
23 TesterMCU_Set_ISM_Mux Pass Pass 00:00.024
24 Set TX on pwr = 240 freq = 902000 debug Pass Pass 00:01.681
25 Delay 10000 Pass Pass 00:10.000
26 TX Test Pass 00:00.000
27 SetSpectrum Pass Pass 00:00.000
28 Get Last Spectrum Mesurment Freq 902000618.38 Pass 00:00.469
29 Get Last Spectrum Mesurment Amp 20 29.96 100 Pass 00:00.000
30 Set TX on pwr = 240 freq = 928000 debug Pass Pass 00:01.680
31 SetSpectrum Pass Pass 00:00.000
32 Get Last Spectrum Mesurment Freq 928000619.10 Pass 00:00.477
33 Get Last Spectrum Mesurment Amp 29.35 Pass 00:00.000
34 Set TX on pwr = 240 freq = 865700 debug Pass Pass 00:01.677
35 SetSpectrum Pass Pass 00:00.000
36 Get Last Spectrum Mesurment Freq 865700498.74 Pass 00:00.486
37 Get Last Spectrum Mesurment Amp 29.88 Pass 00:00.000
38 TX Test - post calibration Pass 00:00.000
39 Restart Reader Pass Pass 00:00.112
40 Delay 6000 Pass Pass 00:06.000
41 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.466
42 SendReaderConfigFile Pass Pass 00:06.763
43 SetSpectrum Pass Pass 00:00.000
44 Set TX on 30 928000 open Pass Pass 00:01.666
45 Get Last Spectrum Mesurment Freq 928996000 928000619.10 928004000 Pass 00:00.487
46 Get Last Spectrum Mesurment Amp 28 28.93 32 Pass 00:00.000
47 SetSpectrum Pass Pass 00:00.000
48 Set TX on 30 902000 open Pass Pass 00:01.675
49 Get Last Spectrum Mesurment Freq 902000618.38 Pass 00:00.476
50 Get Last Spectrum Mesurment Amp 28.82 Pass 00:00.000
51 SetSpectrum Pass Pass 00:00.000
52 Set TX on 30 865700 open Pass Pass 00:01.663
53 Get Last Spectrum Mesurment Freq 865796000 865700498.74 865704000 Pass 00:00.493
54 Get Last Spectrum Mesurment Amp 28 28.14 32 Pass 00:00.000
55 Set TX off Pass Pass 00:00.326
56 Finalize Pass 00:00.000
57 Finalize Pass Pass 00:00.084
Back to List