GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_20241110_112301
startTime
11/12/2024 06:11:07
endTime
11/12/2024 06:11:49
Duration
00:42.528
Status
Stop

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.756
2 PoE : OC Pass 00:00.000
3 PoE : OC : Open circuit test :Turn on the 54V Pass Pass 00:00.193
4 PoE : OC : Set NXP RST Pass Pass 00:00.035
5 Delay 1000ms Pass Pass 00:01.000
6 PoE : OC : Read PoE+ voltage rail (PoE_P_ADC) (mv) 0 Pass 00:00.152
7 PoE : OC : PoE VDD voltage rail (PoE_VDD_ADC) (mv) 1 Pass 00:00.157
8 PoE : OC : PoE VDD voltage rail (PoE_VT15_ADC) (mv) 0 Pass 00:00.161
9 PoE : OC : Measure the current over 54V rail (Vbus54V) (mA) 31 Pass 00:00.030
10 PoE : OC : Read 4.6V rail voltage (ADC_4V6_Load) (mv) 4450 4546 4650 Pass 00:00.033
11 PoE : CC Pass 00:00.000
12 PoE : CC : turn on Load 4.6V rail with external resistor (Load4V6) Pass Pass 00:00.028
13 Delay 100ms Pass Pass 00:00.100
14 PoE : CC : Read PoE+ voltage rail (PoE_P_ADC) (mv) Skip Pass 00:00.000
15 PoE : CC : PoE VDD voltage rail (PoE_VDD_ADC) (mv) Skip Pass 00:00.000
16 PoE : CC : PoE VDD voltage rail (PoE_VT15_ADC) (mv) Skip Pass 00:00.000
17 PoE : CC : Measure the current over 54V rail (Vbus54V) (mA) 235 Pass 00:00.024
18 PoE : CC : Read 4.6V rail voltage (ADC_4V6_Load) (mv) 4322 Pass 00:00.037
19 PoE : CC : turn off Load 4.6V rail with external resistor (Load4V6) Pass Pass 00:00.035
20 PoE : CC : Open circuit test :Turn Off the 54V Pass Pass 00:00.032
21 PA 4.6V : OC Pass 00:00.000
22 PA 4.6V : OC : Turn on the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.029
23 Delay 500ms Pass Pass 00:00.500
24 PA 4.6V : OC : Read 4.6V PA voltage rail 4100 4270 4600 Pass 00:00.027
25 PA 4.6V : OC : Measure the current over 4.6V high current rail 50 200 600 Pass 00:00.027
26 PA 4.6V : CC : Pass 00:00.000
27 PA 4.6V : CC : Load 4.6V PA rail with external resistor Skip Pass 00:00.000
28 Delay 100ms Skip Pass 00:00.000
29 PA 4.6V : CC : Read 4.6V PA voltage rail 2400 Skip 2800 Pass 00:00.000
30 PA 4.6V : CC : Measure the current over 4.6V high current rail 1000 Skip 2000 Pass 00:00.000
31 PA 4.6V : CC : Turn off the external load for 4.6V PA rail Skip Pass 00:00.000
32 MCU LDO : OC Pass 00:00.000
33 MCU LDO : OC : Release NXP RST Pass Pass 00:00.032
34 Delay 500ms Pass Pass 00:00.500
35 MCU LDO : OC : Read 3.5V voltage rail (ADC_3V5_MCU) - (mV) 3300 3536 3600 Pass 00:00.030
36 MCU LDO : OC : Measure the current over 4.6V high current rail (Vbus4V6H) (mA) 15 289 1000 Pass 00:00.027
37 BLE LDO : OC Pass 00:00.000
38 BLE LDO : OC : Release RST of 3.3V BLE LDO (LDO_BLE) Pass Pass 00:00.023
39 Delay 500ms Pass Pass 00:00.500
40 BLE LDO : OC : Read 3.3V BLE voltage rail (ADC_3V3_BLE) - (mV) 3250 3313 3350 Pass 00:00.036
41 BLE LDO : OC : Measure the current over 4.6V high current rail (Vbus4V6H) - (mA) 50 218 1000 Pass 00:00.031
42 LNA LDO : OC Pass 00:00.000
43 LNA LDO : OC : Release RST of 3.3V BLE LDO (LDO_LNA) Pass Pass 00:00.027
44 Delay 100ms Pass Pass 00:00.100
45 LNA LDO : OC : Read 3.3V BLE voltage rail (ADC_3V3_LNA) - (mV) 3250 3317 3350 Pass 00:00.037
46 LNA LDO : OC : Measure the current over 4.6V high current rail (Vbus4V6H) - (mA) 60 231 1000 Pass 00:00.028
47 Flashing NXP Pass 00:00.000
48 TesterMCU_BoardReset Pass Pass 00:00.027
49 Turn on the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.034
50 Set SWD splitter to Out1 Pass Pass 00:00.027
51 Release NXP reset line Pass Pass 00:00.026
52 Jflash_Programming jlink2 workaround Pass Pass 00:02.017
53 Jflash_Programming jlink2 nxp boot Pass Pass 00:01.751
54 Jflash_Programming jlink2 nxp application Pass Pass 00:09.560
55 Set NXP reset line Pass Pass 00:00.026
56 Delay 500 Pass Pass 00:00.500
57 Release NXP reset line Pass Pass 00:00.026
58 Delay 500 Pass Pass 00:00.500
59 Flashing ISM Pass 00:00.000
60 Release all pinout Pass Pass 00:00.026
61 Delay 4000 Pass Pass 00:04.000
62 Set SWD splitter to Out2 Pass Pass 00:00.023
63 Jflash_Programming jlink2 TX boot Pass Pass 00:00.515
64 Jflash_Programming jlink2 TX application Pass Pass 00:00.945
65 Flashing BLE 1 Pass 00:00.000
66 Set SWD splitter to Out1 Pass Pass 00:00.034
67 Release RST of 3.3V BLE LDO (LDO_BLE) Pass Pass 00:00.033
68 Jflash_Programming jlink1 ble Pass Pass 00:01.258
69 Flashing BLE 2 Pass 00:00.000
70 Set SWD splitter to Out2 Pass Pass 00:00.032
71 Jflash_Programming jlink1 ble Pass Pass 00:01.205
72 Flashing BLE 3 Pass 00:00.000
73 Set SWD splitter to Out3 Pass Pass 00:00.034
74 Jflash_Programming jlink1 ble Pass Pass 00:01.224
75 Reader PWR reset Pass 00:00.000
76 Turn OFF the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.034
77 Release NXP reset line Pass Pass 00:00.032
78 Release all pinout Pass Pass 00:00.032
79 Turn ON the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.025
80 Delay 6000 Pass Pass 00:06.000
Back to List