GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_SKIP_CAL_20241111_162917
startTime
11/11/2024 15:10:07
endTime
11/11/2024 15:10:38
Duration
00:31.194
Status
Error

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.751
2 Reader PWR reset Pass 00:00.000
3 Turn OFF the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.026
4 Release NXP reset line Pass Pass 00:00.033
5 Release all pinout Pass Pass 00:00.035
6 Turn ON the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.035
7 Delay 6000 Pass Pass 00:06.000
8 Reader Connect Pass 00:00.000
9 ConnectToReaderTelnet A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond. [::ffff:192.168.0.151]:23 Error 00:21.125
Back to List