GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_20241110_112301
startTime
11/11/2024 15:04:18
endTime
11/11/2024 15:04:45
Duration
00:27.694
Status
Stop

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.795
2 PoE : OC Pass 00:00.000
3 PoE : OC : Open circuit test :Turn on the 54V Pass Pass 00:00.193
4 PoE : OC : Set NXP RST Pass Pass 00:00.035
5 Delay 1000ms Pass Pass 00:01.000
6 PoE : OC : Read PoE+ voltage rail (PoE_P_ADC) (mv) 0 Pass 00:00.165
7 PoE : OC : PoE VDD voltage rail (PoE_VDD_ADC) (mv) 1 Pass 00:00.158
8 PoE : OC : PoE VDD voltage rail (PoE_VT15_ADC) (mv) 0 Pass 00:00.157
9 PoE : OC : Measure the current over 54V rail (Vbus54V) (mA) 32 Pass 00:00.034
10 PoE : OC : Read 4.6V rail voltage (ADC_4V6_Load) (mv) 4450 4547 4650 Pass 00:00.033
11 PoE : CC Pass 00:00.000
12 PoE : CC : turn on Load 4.6V rail with external resistor (Load4V6) Pass Pass 00:00.029
13 Delay 100ms Pass Pass 00:00.100
14 PoE : CC : Read PoE+ voltage rail (PoE_P_ADC) (mv) Skip Pass 00:00.000
15 PoE : CC : PoE VDD voltage rail (PoE_VDD_ADC) (mv) Skip Pass 00:00.000
16 PoE : CC : PoE VDD voltage rail (PoE_VT15_ADC) (mv) Skip Pass 00:00.000
17 PoE : CC : Measure the current over 54V rail (Vbus54V) (mA) 235 Pass 00:00.036
18 PoE : CC : Read 4.6V rail voltage (ADC_4V6_Load) (mv) 4317 Pass 00:00.035
19 PoE : CC : turn off Load 4.6V rail with external resistor (Load4V6) Pass Pass 00:00.038
20 PoE : CC : Open circuit test :Turn Off the 54V Pass Pass 00:00.022
21 PA 4.6V : OC Pass 00:00.000
22 PA 4.6V : OC : Turn on the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.029
23 Delay 500ms Pass Pass 00:00.500
24 PA 4.6V : OC : Read 4.6V PA voltage rail 4100 4272 4600 Pass 00:00.030
25 PA 4.6V : OC : Measure the current over 4.6V high current rail 50 200 600 Pass 00:00.027
26 PA 4.6V : CC : Pass 00:00.000
27 PA 4.6V : CC : Load 4.6V PA rail with external resistor Skip Pass 00:00.000
28 Delay 100ms Skip Pass 00:00.000
29 PA 4.6V : CC : Read 4.6V PA voltage rail 2400 Skip 2800 Pass 00:00.000
30 PA 4.6V : CC : Measure the current over 4.6V high current rail 1000 Skip 2000 Pass 00:00.000
31 PA 4.6V : CC : Turn off the external load for 4.6V PA rail Skip Pass 00:00.000
32 MCU LDO : OC Pass 00:00.000
33 MCU LDO : OC : Release NXP RST Pass Pass 00:00.035
34 Delay 500ms Pass Pass 00:00.500
35 MCU LDO : OC : Read 3.5V voltage rail (ADC_3V5_MCU) - (mV) 3300 3537 3600 Pass 00:00.028
36 MCU LDO : OC : Measure the current over 4.6V high current rail (Vbus4V6H) (mA) 15 300 1000 Pass 00:00.022
37 BLE LDO : OC Pass 00:00.000
38 BLE LDO : OC : Release RST of 3.3V BLE LDO (LDO_BLE) Pass Pass 00:00.031
39 Delay 500ms Pass Pass 00:00.500
40 BLE LDO : OC : Read 3.3V BLE voltage rail (ADC_3V3_BLE) - (mV) 3250 3316 3350 Pass 00:00.038
41 BLE LDO : OC : Measure the current over 4.6V high current rail (Vbus4V6H) - (mA) 50 305 1000 Pass 00:00.035
42 LNA LDO : OC Pass 00:00.000
43 LNA LDO : OC : Release RST of 3.3V BLE LDO (LDO_LNA) Pass Pass 00:00.027
44 Delay 100ms Pass Pass 00:00.100
45 LNA LDO : OC : Read 3.3V BLE voltage rail (ADC_3V3_LNA) - (mV) 3250 3313 3350 Pass 00:00.027
46 LNA LDO : OC : Measure the current over 4.6V high current rail (Vbus4V6H) - (mA) 60 233 1000 Pass 00:00.021
47 Flashing NXP Pass 00:00.000
48 TesterMCU_BoardReset Pass Pass 00:00.028
49 Turn on the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.021
50 Set SWD splitter to Out1 Pass Pass 00:00.031
51 Release NXP reset line Pass Pass 00:00.022
52 Jflash_Programming jlink2 workaround Pass Pass 00:02.023
53 Jflash_Programming jlink2 nxp boot Pass Pass 00:01.806
54 Jflash_Programming jlink2 nxp application Pass Pass 00:09.716
Back to List