GuiSession


stationCode
ReaderFT_01
scandData
000005331,AS000016REVC054424
ATPName
Reader2.0_FullATP_SKIP_CAL_20241111_151639
startTime
11/11/2024 14:23:58
endTime
11/11/2024 14:25:07
Duration
01:08.885
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.798
2 Reader PWR reset Pass 00:00.000
3 Turn OFF the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.028
4 Release NXP reset line Pass Pass 00:00.032
5 Release all pinout Pass Pass 00:00.038
6 Turn ON the 4.6V high current source (Vbus4V6H) Pass Pass 00:00.034
7 Delay 6000 Pass Pass 00:06.000
8 Reader Connect Pass 00:00.000
9 ConnectToReaderTelnet 192.168.0.151 Pass 00:00.314
10 ReaderSetSerialNumber 000005331 Pass 00:00.320
11 ReaderSetMacAddress 1063A39000EB Pass 00:00.212
12 Restart Reader Pass Pass 00:00.105
13 Delay 6000 Pass Pass 00:06.000
14 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.299
15 ReaderGetMacAddress 1063A39000EB Pass 00:00.212
16 SendReaderConfigFile Pass Pass 00:09.913
17 Get Main CPU version 2.3.3+1031 Pass 00:00.103
18 Get TX CPU version 0.17 Pass 00:00.730
19 Get BLE0 CPU version 0.10 Pass 00:00.101
20 Get BLE1 CPU version 0.10 Pass 00:00.715
21 Get BLE2 CPU version 0.10 Pass 00:00.114
22 Start TX (warming up) Pass 00:00.000
23 TesterMCU_Set_ISM_Mux Pass Pass 00:00.032
24 Set TX on pwr = 240 freq = 902000 debug Pass Pass 00:01.679
25 Delay 10000 Pass Pass 00:10.000
26 TX Test Pass 00:00.000
27 SetSpectrum Pass Pass 00:00.000
28 Get Last Spectrum Mesurment Freq 902000143.88 Pass 00:00.481
29 Get Last Spectrum Mesurment Amp 20 29.90 100 Pass 00:00.000
30 Set TX on pwr = 240 freq = 928000 debug Pass Pass 00:01.701
31 SetSpectrum Pass Pass 00:00.000
32 Get Last Spectrum Mesurment Freq 928000381.86 Pass 00:00.478
33 Get Last Spectrum Mesurment Amp 29.28 Pass 00:00.000
34 Set TX on pwr = 240 freq = 865700 debug Pass Pass 00:01.691
35 SetSpectrum Pass Pass 00:00.000
36 Get Last Spectrum Mesurment Freq 865700261.49 Pass 00:00.511
37 Get Last Spectrum Mesurment Amp 29.83 Pass 00:00.000
38 TX Test - post calibration Pass 00:00.000
39 Restart Reader Pass Pass 00:00.115
40 Delay 6000 Pass Pass 00:06.000
41 ReConnectToReaderTelnet 192.168.0.151 Pass 00:00.336
42 SendReaderConfigFile Pass Pass 00:07.660
43 SetSpectrum Pass Pass 00:00.000
44 Set TX on 30 928000 open Pass Pass 00:01.678
45 Get Last Spectrum Mesurment Freq 928996000 928000381.86 928004000 Pass 00:00.469
46 Get Last Spectrum Mesurment Amp 28 29.04 32 Pass 00:00.000
47 SetSpectrum Pass Pass 00:00.000
48 Set TX on 25 865700 open Pass Pass 00:01.682
49 Get Last Spectrum Mesurment Freq 865796000 865700261.49 865704000 Pass 00:00.501
50 Get Last Spectrum Mesurment Amp 23 26.02 27 Pass 00:00.000
51 SetSpectrum Pass Pass 00:00.000
52 Set TX on 30 865700 open Pass Pass 00:01.687
53 Get Last Spectrum Mesurment Freq 865796000 865700261.49 865704000 Pass 00:00.512
54 Get Last Spectrum Mesurment Amp 28 29.81 32 Pass 00:00.000
55 Set TX off Pass Pass 00:00.311
56 Finalize Pass 00:00.000
57 Finalize Pass Pass 00:00.075
Back to List