stationCode
uXiterFT_01
scandData
000006144,AS000018REVC023324
ATPName
uXIter_FT_ATP_Full_20241110_135549
startTime
11/11/2024 11:42:58
endTime
11/11/2024 11:43:08
Duration
00:10.346
Status
Fail

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:03.901
2 OC :: 12V to 4V DCDC Pass 00:00.000
3 Turn ON 12V source Pass Pass 00:00.018
4 Enable 4V DCDC Pass Pass 00:00.030
5 Delay 1000 Pass Pass 00:01.000
6 Read DUT 4V voltage rail -uX1 3800 3945 4100 Pass 00:00.438
7 Measure the current over 12v current rail 65 Pass 00:00.426
8 CC :: 12V to 4V DCDC Pass 00:00.000
9 Load 4V rail with external resistor Pass Pass 00:00.018
10 Delay 1000 Pass Pass 00:01.000
11 Read DUT 4V voltage rail -uX1 3127 Pass 00:00.431
12 Measure the current over 4v current rail 786 Pass 00:00.404
13 Turn off the external load Pass Pass 00:00.020
14 OC :: 4V to 3.3V LDO Pass 00:00.000
15 Enable 3.3V LDO Pass Pass 00:00.025
16 Delay 1000 Pass Pass 00:01.000
17 Read DUT 3.3V voltage rail 3100 53 3360 Fail 00:00.442