GuiSession


stationCode
ReaderEOL_03
scandData
000006307,NR000005
ATPName
ReaderSystemATP_Full_AoA_20241106_155158
startTime
11/11/2024 07:14:41
endTime
11/11/2024 07:19:23
Duration
04:42.123
Status
Pass

Test Results

index TestName Min Limit ResultAnswer Max Limit ResultStatus Duration
0 Initialize Pass 00:00.000
1 init Pass Pass 00:04.302
2 ReaderTypeSelect HB Pass 00:00.000
3 Reader communication Pass 00:00.000
4 ConnectToReaderTelnet 192.168.0.100 Pass 00:00.624
5 ReaderReset Pass Pass 00:00.111
6 Delay 4000ms Pass Pass 00:04.000
7 ConnectToReaderTelnet 192.168.0.100 Pass 00:00.339
8 Reader Get Serial Number 000006307 Pass 00:00.112
9 Update Session Info Pass 00:00.000
10 Reader Get Mac Address 1063A39001BB Pass 00:00.224
11 SendReaderConfigFile Pass Pass 00:09.185
12 Get Main CPU version 2.1.1+1029 Pass 00:00.111
13 Get TX CPU version 0.15 Pass 00:00.103
14 Get BLE0 CPU version 0.10 Pass 00:00.113
15 Get BLE1 CPU version 0.10 Pass 00:00.115
16 Get BLE2 CPU version 0.10 Pass 00:00.101
17 AoA Calibration Pass 00:00.000
18 ReaderAoACla Pass Pass 01:05.888
19 BIST Pass 00:00.000
20 ReaderEthernetCapabilitiesCheck Pass Pass 00:00.105
21 ReaderTxGetTemp 30.12 Pass 00:00.109
22 RF Tx Test Pass 00:00.000
23 Set TX on pwr = 29 open Pass Pass 00:00.453
24 SetSpectrum 865700000 Pass Pass 00:00.000
25 Set Reader TX freq 865700 Pass Pass 00:00.305
26 Reader SyncTime Pass Pass 00:00.621
27 Delay 5500ms Pass Pass 00:05.500
28 GetSpectrumMesurment - return freq 865696000 865701071.19 865704000 Pass 00:00.501
29 Get Last Spectrum Mesurment Amp 25 28.04 36 Pass 00:00.000
30 SetSpectrum 928000000 Pass Pass 00:00.000
31 Set Reader TX freq 928000 30 Pass Pass 00:00.304
32 Reader SyncTime Pass Pass 00:00.631
33 Delay 4000ms Pass Pass 00:04.000
34 GetSpectrumMesurment - return freq 927996000 928001147.39 928004000 Pass 00:00.483
35 Get Last Spectrum Mesurment Amp 25 30.24 36 Pass 00:00.000
36 SetSpectrum 865700000 Pass Pass 00:00.000
37 Set Reader TX freq 865700 25 Pass Pass 00:00.436
38 Reader SyncTime Pass Pass 00:00.628
39 Delay 4000ms Pass Pass 00:05.500
40 GetSpectrumMesurment - return freq 865696000 865700833.94 865704000 Pass 00:00.494
41 Get Last Spectrum Mesurment Amp 20 24.28 30 Pass 00:00.000
42 Set TX off Pass Pass 00:00.317
43 Delay 4000ms Pass Pass 00:05.500
44 BLE RX Test ch 37 Pass 00:00.000
45 ReaderBLE_PreTestConfig Pass Pass 00:05.439
46 ReaderBLEtest ch 37 ant 1 -55 -40.45 -25 Pass 00:05.984
47 ReaderBLEtest ch 37 ant 2 -55 -39.11 -25 Pass 00:05.976
48 ReaderBLEtest ch 37 ant 3 -55 -40.45 -25 Pass 00:05.984
49 ReaderBLEtest ch 37 ant 4 -55 -33.51 -25 Pass 00:05.994
50 ReaderBLEtest ch 37 ant 5 -55 -38.45 -25 Pass 00:05.923
51 ReaderBLEtest ch 37 ant 6 -55 -31.94 -25 Pass 00:05.964
52 ReaderBLEtest ch 37 ant 7 -55 -40.45 -25 Pass 00:05.994
53 BLE RX Test ch 38 Pass 00:00.000
54 ReaderBLE_PreTestConfig Pass Pass 00:05.416
55 ReaderBLEtest ch 38 ant 1 -55 -39.23 -25 Pass 00:05.968
56 ReaderBLEtest ch 38 ant 2 -55 -30.47 -25 Pass 00:05.956
57 ReaderBLEtest ch 38 ant 3 -55 -40.49 -25 Pass 00:05.916
58 ReaderBLEtest ch 38 ant 4 -55 -31.45 -25 Pass 00:05.907
59 ReaderBLEtest ch 38 ant 5 -55 -37.91 -25 Pass 00:05.966
60 ReaderBLEtest ch 38 ant 6 -55 -35.53 -25 Pass 00:05.933
61 ReaderBLEtest ch 38 ant 7 -55 -36.67 -25 Pass 00:06.053
62 BLE RX Test ch 39 Pass 00:00.000
63 ReaderBLE_PreTestConfig Pass Pass 00:05.448
64 ReaderBLEtest ch 39 ant 1 -55 -38.45 -25 Pass 00:05.955
65 ReaderBLEtest ch 39 ant 2 -55 -35.45 -25 Pass 00:05.938
66 ReaderBLEtest ch 39 ant 3 -55 -42.10 -25 Pass 00:05.970
67 ReaderBLEtest ch 39 ant 4 -55 -38.45 -25 Pass 00:06.013
68 ReaderBLEtest ch 39 ant 5 -55 -35.45 -25 Pass 00:05.954
69 ReaderBLEtest ch 39 ant 6 -55 -32.95 -25 Pass 00:05.980
70 ReaderBLEtest ch 39 ant 7 -55 -33.45 -25 Pass 00:05.977
71 Print Lable Pass 00:00.000
72 PrintReaderLable Pass Pass 00:02.479
73 Finalize Pass 00:00.000
74 Finalize Pass Pass 00:00.001
Back to List